RAM
Links
Literature
Our Customers
Sales Reps
Parts/Service
Training
Warranty
Heating
Options
Direct-fired
2000 Series
4000 Series
Indirect-fired
7000 Series
8000 Series
Electric
Steam/Hot Water
Controls
Options
ICS II
ICS III
Non-DDC
Cooling
Options
Coil Sections
Evap Cooling
Special
Needs
Variable-speed
Auto plants
Food & Drug
Construction
Overhead doors
Car wash dryers
|
 |
 
|
 |
Are high energy bills
and poor operating efficiency getting you down? Let Rapid's
Variable Speed Drive (VSD) option help you increase your heating
efficiency and reduce your operating costs.
|
 |
 |

The VSD advantage

Rapid's Variable Speed Drive option synchronizes the
fan motor's operating speed with the building's exhaust
needs. When exhaust fans aren't operating at full capacity,
Rapid's VSD system reduces the fan speed to the minimum
level required to meet your building's pressurization
needs.

Most facilities only use a small fraction of their maximum
load at any given time. By matching fan speed to your
actual heating-load or cooling-load needs, you reduce
your energy costs and maximize your operating efficiency.

Rapid's VSD option is ideal for:
| |
Any
building with variable exhaust loads |
| |
Any
building needing additional CFM for summer cooling |
| |
Automotive-refinishing
facilities |
| |
Warehouses,
distribution centers, and a wide range of other
facilities |
|
 |

Increase
your heating efficiency

Rapid's heating systems already offer the best heating
efficiency available. Now, Rapid takes you to the next
level by combining exceptional fan
efficiency with the excellent turndown
efficiency of a variable speed drive (often
50% better than a comparable constant-speed drive).

Rapid's easy-to-use control technology maintains the
perfect flow ratio (for both gas and air) for every
condition.

Our sophisticated, built-in setup and diagnostic tools
are "invisible" during normal operation, yet
immediately available whenever you need them.

Reduce your operating costs

Rapid's factory-installed VSD option reduces field-installation
costs.

And, with Rapid's Variable Speed Drive model, you can
cut your electrical costs dramatically (see below) as
well as save up to 50% on natural gas costs (when compared
to a similar model using a constant speed drive).

Estimated annual energy
savings based on Motor HP

20 MHP...............$7,300
30 MHP..............$10,892
40 MHP..............$14,500
50 MHP..............$18,200
Rapid's VSD model is ETL listed
and has been tested and approved in accordance with
stringent new ANSI Z83.4 standard for make-up air. |
Request information: online
or at 800-536-3461

|

Download HVAC
systems with Variable Speed Drive (4 pages) 668k
 |
|
|